Set-up, warranty, maintenance and use of the Cavitron Jet Plus Ultrasonic Scaling Unit.
TLDRThe Caviton Jet Plus G137 is a dental unit with a 2-year warranty, voided by modifications or accidental damage. It includes an airline and waterline with a filter, which must be correctly inserted to avoid flooding and voiding the warranty. The unit operates with a standard Kettle lead and a cordless tap-on foot pedal using AA batteries. The foot pedal can lose Bluetooth connection, which can be reestablished by checking batteries and following specific steps. The Caviton Jet Plus has a tap-on function for the foot pedal and a Proy mode for air polishing with a mint-flavored powder. Regular maintenance is crucial, including checking for proper cavitation, adjusting power and water settings, and using distilled water or an antibacterial solution. A weekly waterline bleaching protocol is recommended to prevent scale buildup. If issues persist, the service department should be contacted for assistance.
Takeaways
- โ๏ธ The Caviton Jet Plus G137 comes with a 2-year warranty, which is void if the unit is modified or damaged accidentally.
- ๐ The power cable is standard, and the cordless tap-on foot pedal requires AA batteries with an optional cable available for when batteries run out.
- ๐ง It is crucial to correctly insert the airline and waterline into the back of the unit, with clear indicators for water (white ring) and air (black ring) to prevent flooding and voiding the warranty.
- ๐ด To switch the unit on, press the button underneath the front, and ensure the foot pedal has batteries to operate automatically.
- ๐ If the foot pedal loses Bluetooth connection, reconnection involves turning off the Caviton, checking the batteries, and using a specific sequence of button presses.
- ๐ ๏ธ The foot pedal operates in both standard (constant pressure) and tap-on (press to start/stop) modes, with a delay in command response.
- ๐ฟ Before scaling, fill the Jetmate with water until a bubble appears, ensuring the insert is straight and clear of the Jetmate's sides.
- โ๏ธ Inserts must be measured for length tolerances to be effective, and different settings are used based on the type and age of the insert.
- ๐ฅ If an insert or Jetmate heats up, stop scaling, check the water level, and adjust the power settings; never increase water to cool the insert.
- ๐ The Proy mode requires checking the powder level and using dry powder; a blocked airline can be cleared by pushing air through the system.
- ๐ The Caviton Jet Plus should be used with distilled water or an antibacterial solution, with a weekly bleaching protocol to prevent biofilm and scale buildup.
Q & A
What is the warranty period for the Caviton Jet Plus tap-on g137, 30k unit?
-The Caviton Jet Plus tap-on g137, 30k unit comes with a 2-year warranty that covers normal usage.
What could void the warranty of the Caviton Jet Plus?
-The warranty could be voided by any modifications, accidental damage, or the use of competitor's inserts.
What type of batteries does the cordless tap-on foot pedal of the Caviton Jet Plus require?
-The cordless tap-on foot pedal requires AA batteries.
How can you avoid flooding the unit and voiding the warranty when connecting the waterline and airline?
-Ensure that the waterline and airline are not mixed up. The waterline should be connected to the white ring labeled 'water' and the air cable to the black ring labeled 'air'.
What should you do if the foot pedal loses Bluetooth connection to the Caviton?
-To reconnect, switch off the Caviton, unscrew the base plate from the foot pedal, check the batteries are seated properly, replump any squished felt wedges, and change batteries if necessary. Then, switch on the Caviton, hold down the purge button until all icons flash, and press the small red button on the base foot pedal until all icons flash in unison.
How do you switch on the Caviton Jet Plus?
-The switch button is located underneath the front of the unit. When pressed, all the lights on the screen will flash in a circle.
What should you do if the Caviton Jet Plus unit has an updated tap-on foot pedal function?
-Ensure that you use the correct foot pedal that is compatible with the correct version of the Caviton Jet Plus.
What is the recommended method to fill the jetmate before inserting a Caviton insert?
-Fill the jetmate while vertical until a bubble of water appears at the top, then drop the insert in, ensuring it is straight and clear of the jetmate's sides.
What should you do if an insert or jetmate starts to heat up during use?
-Stop scaling immediately, remove the insert, ensure the jetmate is full of water, replace the insert, and turn the power down.
How should the Caviton Jet Plus be used with the air polishing mode?
-The Caviton Jet Plus should be used with a Caviton Jet Fresh, which is a mint-flavored aluminum trihydroxide powder. The proof insert should always have the cleaning rod inserted to keep it unblocked.
What is the recommended procedure to clear the system of scale in the Caviton Jet Plus?
-Use a 10% solution of thin white bleach, run it through the system using the purge button, and then clean out the water bottle and replace it with distilled or deionized water.
How should the Caviton Jet Plus be maintained to prevent waterline issues?
-Use distilled water or water with an antibacterial solution, run the water line dry at night, flush water through the unit at the start of the day, and follow a weekly waterline bleaching protocol.
Outlines
๐ Introduction to the Cavaton Jet Plus
The first paragraph introduces the Cavaton Jet Plus dental unit, highlighting its features and usage instructions. Key points include: 2-year warranty valid for normal use, void if modified or damaged; standard power cable; cordless tap-on foot pedal with AA batteries; importance of correctly inserting the airline and waterline to avoid flooding and voiding the warranty; how to switch the unit on and off; using the correct foot pedal version; reconnecting the Bluetooth foot pedal; using the foot pedal in standard or tap-on mode; preparing and inserting the Cavaton insert correctly; adjusting power and water settings; and troubleshooting common issues like insert heating up or not cavitating.
๐จ Troubleshooting and Maintenance
The second paragraph focuses on troubleshooting and maintenance for the Cavaton Jet Plus. It covers: checking the stone mate or handpiece cable if the service light is on; how to fix a blocked airline; using the unit with distilled water or antibacterial solution; running the water line dry at night and purging at the start of the day; weekly waterline bleaching protocol; changing the water filter; and contacting the service department for unresolved issues or repairs.
๐ Air Polishing Mode Instructions
The third paragraph provides detailed instructions for using the air polishing mode of the Cavaton Jet Plus. It explains: checking the powder level in the pot; how to fill the pot correctly; using the correct Cavaton Jet Fresh powder; clearing water from the airline if lines are mixed up; pressurizing the system with powder; adjusting the powder output level; using the proof insert correctly; cleaning the insert after use; selecting the desired proy mode setting; using the proy insert at a 45ยฐ angle; testing the proy mode on an old coin; unblocking the airline and proy insert if needed; and the importance of careful, methodical use to avoid spraying powder on the patient.
Mindmap
Keywords
๐กCavaton Jet Plus
๐กWarranty
๐กFoot pedal
๐กAirline and waterline
๐กInserts
๐กPower and water settings
๐กBluetooth connection
๐กAir polishing mode
๐กMaintenance
๐กTroubleshooting
Highlights
Cavaton Jet Plus G137 is a cordless dental unit with a 2-year warranty, voided by modifications or accidental damage.
The foot pedal operates on AA batteries and has an optional cable for when batteries run out.
It is crucial not to mix up the waterline and airline to avoid flooding the unit and voiding the warranty.
The Cavaton Jet Plus includes an airline and waterline with filter, which should be correctly inserted to avoid damage.
To switch on the unit, press the button underneath the front, and the foot pedal will automatically turn on if batteries are present.
If the foot pedal loses Bluetooth connection, reconnection can be achieved by turning off the Cavaton and checking battery seating.
The foot pedal has a standard function with constant pressure and a tap-on function that allows toggling the unit on and off.
Before scaling, fill the Jetmate with water until a bubble appears, ensuring the insert is straight and clear of the Jetmate sides.
Measure inserts before use to ensure they are within length tolerances for effectiveness.
Adjust the power and water settings based on the type and age of the insert for optimal performance.
The Boost setting should only be used for short bursts to remove heavy plaque deposits.
If an insert heats up during use, stop scaling, check the Jetmate water level, and adjust power settings.
For the air polishing mode, ensure the powder pot is filled correctly with dry powder and the Cavaton Jet Fresh powder is used.
Pressurize the powder system by turning on the Cavaton Jet Plus after filling the powder pot.
Adjust the powder dial on the powder pot to control the amount of powder used in the air polishing mode.
Use the cleaning rod to remove powder from the Proy insert after use and before autoclaving.
Select the appropriate Proy mode setting (none, short, medium, long) based on the application to prevent accidental powder spray.
Hold the Proy insert at a 45ยฐ angle 1-2mm from the tooth surface and use a large evacuation suction tip for safety.
Perform regular maintenance like checking for blockages, changing filters, and running a weekly waterline bleaching protocol.
Contact the service department for advice or repair if issues persist after following the provided maintenance guidelines.
Transcripts
Browse More Related Video
Set-up, warranty, maintenance and use of the Cavitron SPS Select with Reservoir Ultrasonic Scaler
Cavitronยฎ 300 Series Ultrasonic Scaling System - Overview | Dentsply Sirona
Cavitron Plus Set-Up Guide/Tutorial With Insert Overview | Dentsply Sirona
How to Clean Analytical Glassware
Do Water Filters Really Purify Your Water? | Talking Point | Full Episode
How Does a Pedal Point Work? - Music Theory
5.0 / 5 (0 votes)
Thanks for rating: