Set-up, warranty, maintenance and use of the Cavitron SPS Select with Reservoir Ultrasonic Scaler

Dentsply Sirona UK
1 Feb 202406:38
EducationalLearning
32 Likes 10 Comments

TLDRThe Caviton Select G124 30k is a dental unit designed for light scaling, featuring a 2-year warranty, a detachable water bottle, and a basic power dial with foot pedal control. It's suitable for domiciliary visits or when a pressurized water system isn't available. The unit includes a standard sterate with a 6-month warranty and a free FSI 1000 insert with a 3-month warranty. Assembly is straightforward, and the unit requires regular maintenance, including filter checks and weekly waterline bleaching to prevent scale buildup. For optimal performance, use distilled water or an antibacterial solution, and adjust power and water settings according to the type and age of the inserts. The unit is not designed for heavy-duty, all-day use. If issues arise, troubleshooting tips are provided, and the service department can assist with part replacements or repairs.

Takeaways
  • 🔧 The Caviton Select G124 30k comes with a 2-year warranty for normal usage, but modifications or accidental damage void the warranty.
  • 💧 The unit includes a standard sterate with a 6-month warranty and a free FSI 1000 insert with a 3-month warranty.
  • 🧰 Assembly is straightforward, and the unit can be used with or without a pump and reservoir, ideal for domiciliary visits or transport between surgeries.
  • 🚿 Designed for light work with a detachable water bottle and pump, which may require more frequent servicing and repair.
  • 🔩 The Caviton is an analog unit featuring a basic power dial, cabled foot pedal, and handpiece cable water dial, not intended for all-day heavy scaling.
  • 🔌 The Caviton SPs Select can be used with a surgery's own pressurized water bottle system if a female AD connection is available, offering a quieter operation.
  • 💰 For practices with an existing AD connection looking to invest in a new unit, a more advanced tabletop unit like the digital Caviton 300 is recommended.
  • 🔄 To prepare the unit, attach the water reservoir to the pump, ensuring a tight connection, and regularly check the filter for discoloration indicating the need for replacement.
  • 💦 Fill the water reservoir to 2/3 with irrigant or water, ensuring no air is present, for a standard scaling procedure.
  • 🚫 The pump will produce a constant whining sound when the unit is on, and the water bottle or cap cannot be unscrewed during operation.
  • 🧴 The unit should be used with distilled water or water with an antibacterial solution, and a weekly waterline bleaching protocol is recommended to prevent scale buildup.
  • 📏 Inserts should be measured before use to ensure they are within length tolerances for efficiency and effectiveness, with measurement cards available from the service department.
Q & A
  • What is the warranty period for the Caviton select g124 30k unit?

    -The Caviton select g124 30k unit comes with a 2-year warranty, which is valid for normal usage conditions.

  • Under what circumstances would the warranty for the Caviton select g124 30k be void?

    -The warranty would be void if there are any modifications or accidental damage to the unit.

  • What is included in the standard package of the Caviton select g124 30k?

    -The standard package includes a sterate with a six-month warranty and a free FSI 1000 insert with a 3-month warranty from the date of purchase.

  • What is the purpose of the detachable water bottle and pump in the Caviton unit?

    -The detachable water bottle and pump are designed for light work and are more likely to require regular surfacing and repair. They allow the unit to be used outside of the dental practice for domiciliary visits or transported between surgeries.

  • How is the Caviton SPs select connected to a surgery's own pressurized water bottle system?

    -The Caviton SPs select can be connected to a female AD connection, which allows for less change of water and quieter operation as the pump is not required.

  • What is the cost of plumbing in a female AD water connection by a third party engineer?

    -The cost of plumbing in a female AD water connection by a third party engineer is approximately £100.

  • How should the Caviton unit be assembled?

    -First, attach the water reservoir to the pump by twisting it clockwise until tight against the large O-ring. Then, connect the pump and water bottle, align the back of the Caviton unit, which is the triangular section, and slide it into place. Finally, plug in the power cable, foot pedal cable, and handpiece cable with a detachable sterate.

  • What should be done to fill up the water reservoir of the Caviton unit?

    -Turn off and depressurize the Caviton, unscrew the small white cap at the front of the reservoir bottle, and fill up to 2/3 of the bottle with irrigant or water. If air is heard coming from the cap, switch the unit off, unscrew the cap, and then retighten the cap.

  • Why is it recommended to use the Caviton SPs select with distilled water or water with an antibacterial solution?

    -Using distilled water or water with an antibacterial solution helps to keep the lines clean of biofilm and prevents scale or debris buildup.

  • What is the recommended procedure for weekly waterline maintenance to remove scale?

    -A 10% solution of bleach water should be run through the system and then replaced by the water normally used in the water bottle, such as RO water or distilled water, to flush out any remaining bleach.

  • How should the Caviton inserts be used for optimal efficiency and effectiveness?

    -Inserts should be used on the water and power setting dependent upon the type and age of inserts. The power dial and water dial should be adjusted until a consistent drip with a light hue is achieved. Overuse of power can cause insert wear and patient discomfort.

  • What should be done if an insert or sterate starts to heat up during use?

    -Stop scaling immediately, remove the insert, ensure the sterate is full of water, replace the insert, and turn the power down. Simply turning up the water will not cool down the insert.

Outlines
00:00
🔧 Overview and Setup of the Cavaton Select G124 30k Unit

The Cavaton Select G124 30k is a dental unit designed for light work and is often used outside dental practices for domiciliary visits. It comes with a 2-year warranty, voided by modifications or accidental damage. The unit includes a standard sterate with a six-month warranty and a free FSI 1000 insert with a 3-month warranty. Assembly involves attaching the water reservoir to the pump and connecting the unit with its cables. The unit is not designed for heavy-duty scaling and has a small water reservoir. It can be connected to a pressurized water bottle system via a female AD connection for quieter operation. Regular maintenance includes checking the filter for discoloration and replacing it when necessary, and a weekly waterline bleaching protocol is recommended to prevent scale buildup.

05:01
💧 Operation and Maintenance of the Cavaton Select G124 30k

The Cavaton Select G124 30k should be used with distilled water or an antibacterial solution to keep the water lines clean. It is important to run the water line dry at night and flush it at the start of the day to clear any biofilm. The unit operates with a power dial and foot pedal, and the water and power settings should be adjusted based on the type and age of the dental inserts used. Overuse of power can lead to insert wear and patient discomfort. The Boost setting is for short bursts to remove heavy plaque deposits. If an insert heats up, it should be removed and the sterate checked for sufficient water. Inserts should be used within their length tolerances for efficiency. If cavitation issues occur, check the insert stack and sterate, and if necessary, replace parts or contact the service department for assistance.

Mindmap
Keywords
💡Cavaton Select G124 30k
The Cavaton Select G124 30k is a specific model of a dental unit, likely used for scaling and cleaning procedures in dental practices. It is mentioned as having a 2-year warranty for normal usage, which signifies its importance as a durable and reliable piece of dental equipment. The unit's design allows for both stationary and portable use, highlighting its versatility in different dental settings.
💡Warranty
A warranty is a guarantee provided by the manufacturer that the product will be free from defects or issues under normal use for a specified period. In the context of the video, the Cavaton unit comes with a 2-year warranty, which is void if there are modifications or accidental damage. This keyword is significant as it reflects the manufacturer's confidence in the product's quality and longevity.
💡Sterate
The sterate is a component of the dental unit, which comes with a 6-month warranty. It is a critical part used in conjunction with the dental handpiece for cleaning and scaling procedures. The mention of the sterate in the script emphasizes the need for regular maintenance and replacement parts to ensure the unit's optimal performance.
💡FSI 1000 Insert
The FSI 1000 insert is an accessory that comes with a 3-month warranty from the date of purchase. It is used with the Cavaton unit for specific dental procedures. The mention of the FSI 1000 insert in the script indicates that the unit is customizable and can be equipped with different tools to suit various dental applications.
💡Domiciliary Visits
Domiciliary visits refer to the practice of providing medical or dental services at a patient's home. The script mentions that the Cavaton unit is chosen for use outside of the dental practice for such visits, indicating that the unit is portable and suitable for on-the-go dental care.
💡Detachable Water Bottle and Pump
A detachable water bottle and pump are features of the Cavaton unit that allow for easy transportation and refilling. The script highlights that due to this design, the unit may require more frequent maintenance, which is essential for understanding the operational aspects and practical considerations of using the unit.
💡Analog Unit
An analog unit, as mentioned in the script, refers to a device that uses traditional, non-digital technology. The Cavaton unit is described as an analog unit with basic functionality, which suggests that it may not have advanced features found in more modern, digital dental equipment.
💡Waterline Bleaching Protocol
The waterline bleaching protocol is a recommended maintenance procedure to clean the water lines of the dental unit and prevent biofilm buildup. The script specifies using a 10% bleach solution, which is essential for maintaining the unit's hygiene and performance. This keyword is significant as it relates to the ongoing care required to keep the unit functioning properly.
💡Insert Measurement
Insert measurement refers to the process of ensuring that the dental inserts used with the Cavaton unit are within the correct length tolerances. The script advises measuring the inserts before use to ensure efficiency and effectiveness, which is crucial for the quality of dental procedures performed with the unit.
💡Cavitron SPs Select
The Caviton SPs Select is a specific model of the dental unit that can be used with a surgery's own pressurized water bottle system if a female AD connection is available. This keyword is important as it suggests an alternative setup for the unit that may offer benefits such as reduced water change frequency and quieter operation.
💡Cavitron 300
The Caviton 300 is a newer, digital model of the dental unit that is suggested for those looking to invest in a more advanced and feature-rich tabletop unit. The mention of the Caviton 300 in the script provides a comparison to the Cavaton Select G124 30k and indicates a progression in dental technology.
Highlights

The Caviton Select G124 30k is a dental unit with a 2-year warranty, voided by modifications or accidental damage.

Comes with a standard sterate and a free FSI 1000 insert, each with their respective warranty periods.

Assembly is straightforward, allowing use with or without a pump and reservoir.

Designed for light work, with a detachable water bottle and pump, potentially requiring more frequent servicing.

Features an analog power dial, cabled foot pedal, and handpiece cable water dial.

Not designed for heavy daily use; intended for light scaling due to basic functionality and small water reservoir.

Can be used with a surgery's own pressurized water bottle system via a female AD connection.

A third-party engineer can install a female AD water connection for approximately £100.

For new cavitron investments, a more advanced tabletop unit like the digital Caviton 300 is recommended.

The water reservoir connects to the pump, with a filter that requires regular checks for discoloration.

The Caviton unit is ready for cable connections once the pump and water bottle are connected.

The power cable is standard, and the foot pedal cable does not have a COR option.

To fill the water reservoir, the unit must be turned off and depressurized.

The pump creates a constant whining sound when the unit is turned on.

Option to use a water cable and plug into a female water connection for quieter operation.

Should be used with distilled water or water with an antibacterial solution to prevent biofilm.

A weekly waterline bleaching protocol is recommended to remove scale.

Inserts should be measured for length tolerances before use for efficiency and effectiveness.

Inserts should be used on the appropriate water and power setting based on type and age.

The Boost setting is for short bursts to remove heavy deposits of plaque.

If an insert or sterate heats up, stop scaling, ensure the sterate is full, and adjust the power.

Faulty parts can be identified by process of elimination, and the service department can provide part codes.

Transcripts
Rate This

5.0 / 5 (0 votes)

Thanks for rating: